| Unit Capacity |
Suction
50 psig
75 psig
100 psig
125 psig
150 psig |
Discharge
1200 psig
1200 psig
1200 psig
1200 psig
1200 psig |
Flow
3.24 MMSCFD
4.35 MMSCFD
4.70 MMSCFD
4.94 MMSCFD
5.50 MMSCFD |
| Number of Stages |
3 stage |
| Service |
Sour Service |
| Design Pressure –
High Pressure Side |
1600 psig |
| Discharge Pressure–
Operating Range |
1000 to 1440 psig |
| Compressor |
Ariel JGH - 4 throw
Compressor |
| Engine Driver |
810 HP Caterpillar 3512 TALE |
| Cooler |
Propak Engine Driven vertical
induced draft style |
| Scrubbers |
1st Stage – 24 inch O.D. x 64 inch
S/S
2nd Stage – 20 inch O.D. x 60 inch
S/S
3rd Stage – 16 inch O.D. x 56 inch
S/S |
| Bottles |
Designed for 2% peak to
peak pulsation |
| Control Panel |
PLC based
with Colour Touch Screen |
| Skid Size |
20 foot wide x 40
foot long skid – 30 inch beam depth |
| Building Size |
20 foot wide x 30
foot long – shop erected building included |